MIDAS/FEA的水化热分析—以克地坝陵河特大桥大体积混凝土承台为例

来源:抵帆知识网
・96・ 价值工程 MIDAS/FEA 的水化热分析 ——以克地坝陵河特大桥大体积混凝土承台为例 Hydration Heat Analysis of MIDAS/FEA: Taking the Large Volume Concrete Pile Caps of the Extra Large Bridge f Lionghe in Kedi Dam for Example 刘海涛LIU Hai—tao (中铁二十局集团第六工程有限公司,西安710032) (The No.6 Engineering Co.,Ltd.of China Railway 20th Bureau Group,Xi an 7 10032,China) 摘要:在承台施工中,大体积混凝土得到广泛使用。为了解决施工中出现的水化热问题,本文以克地坝陵河特大桥连续梁主墩 3}}承台为例,采用MIDAS/FEA有限元分析软件对该承台的水化热效果进行分析,并根据MIDAS/FEA测得的相关数据,同时提出相 应的政策建议,为同类工程施工提供参考依据,进而实现价值工程管理的目的。 Abstract:The large volume concrete is widely used in the construction of pile caps.In order to solve the heat of hydration in the construction,this paper takes 3#pile cap of the main pier continuous beam of the large bridge of Linghe in Kedi dam for example。and uses the finite element analysis software of MIDAS/FEA to analyze the heat of hydration effect of the pile cap.According to the measured data of MIDAS/FEA,the related policy suggestions are put forward to provide references for the similar engineering construction and implement the management of value engineering. 关键词:MIDAS/FEA;温控施工;冷却管;数值分析;有限元 Key words:MIDAS/FEA;tempera nstuctrion;cooling pipe;numerical anaXysis;finite element中图分类号: . .ture control coU445 57 文献标识码:A文章编号:1006 4311(2015)10—0096—06 —O引言 在混凝土水化热的问题上,业界主要利用ANSYS建 模对大体积混凝土的温度应力进行仿真分析,快速正确地 读取温度场数据是分析的关键步骤。但是,由于其图形驱 动技术支持的界面可管理性和操作性相对较差,无法完成 复杂模型的建模,因此结构分析效果大大降低了可信度, 影响工作效率,这是该软件的局限性。 MIDAS/FEA是“目前唯一全部中文化的土木专用非 线性及细部分析软件”,并且融入了MIDAS强大的线性、 非线性分析内核,是一款专门适用于土木领域的高端非线 性分析和细部分析软件,该软件在工程项目结构、正常使 用发挥着重要的作用,尤其大体积混凝土广泛使用的今 天,MIDAS/FEA的重要性更加凸显。在MIDAS/FEA中通 过建立模型,利用模型对混凝土的水化热进行分析,同时 测得相应的温度拉应力,进而对相应龄期的混凝土容许拉 应力进行判断,进一步提高混凝土构造物的质量。 1工程概况 图1承台结构尺寸及立体图 克地坝陵河特大桥位于贵州省关岭县坡贡镇,其中心 里程:D2K845+173,桥长:525.738m。孔跨布置为:lx32m+ 2模型建立 由于承台及垫块属于对称结构,故取承台及垫块结构 (88+168+88)ITI连续刚构+4x32m简支箱梁。 其2#墩台位于镇水公路深路堑边坡上,3#墩台位于 丫口l#滑坡体上,承台为大体积混凝土结构,尺寸为 36.4m(横桥向)x19.0m(顺桥向)x5.0m(厚度),项部设置垫 块,尺寸为26m(横桥向)xl2m(顺桥向)xlm(厚度),混凝 土设计为C35,要求承台及垫块一次性浇筑,浇筑方量为 377Om 。 承台结构尺寸及立体图见图1。 作者简介:刘海涛【1979一),男,山东威海人,毕业于山东农业大 学,研究方向为土木工程。 的1/4部分进行建模和分析,另外取lm厚地基模拟结构 进行分析,因地基模拟结构有一定的比热和热传导率,以 便正确模拟显示地基顶部混凝土热量传递过程,桩基对承 台结构的温度影响未计入。 在MIDAS/FEA中建立模型如图2所示(为了体现直 观侧面效果,则尺寸建立以1/4大小为准),单元尺寸大小 选取0.5~lm,则地基划分为1868个单元,承台划分为 3705个单元,垫块划分为624个单元,其中各网格尺寸 为:地基(长×宽×厚):25mx15mxO.2m,承台(长×宽×厚): 18.2rex9.5mx5m,垫块(长×宽×厚):13mx6mxlm。 坝陵河大体积承台1/4模型见图2。 Value Engineering ・101・ 建筑施工中钢结构技术分析 Analysis on the Steel Structure Technology in the Building Construction 孔祥伟KONG Xiang—wei (山东莱钢建设有限公司建筑安装分公司,莱芜271 126) (Construction and Installation Branch of Shandong Laigang Construction Co.,Ltd.,Laiwu 27 1 1 26,China) 摘要:随着我国科学技术的快速发展,建筑施工技术水平不断提高,钢结构关乎着建筑工程的施工质量,为此,在建筑施工中,对 钢结构技术要求比较高。本文对建筑施工中,钢结构技术的优点与缺点进行分析,并探讨钢结构技术要点,把握好钢结构技术,从而保 证施工质量。 Abstract:With the rapid development of science and technology in China,the level of building constuctrion has unceasingly enhanced.The steel stucture isr related to the quality of building construction,SO,the requirements of steel stuctrure technology are quite high.This paper analyzes the advantages and disadvantages of steel structure technology in the building construction and discusses the main technical points of steel structure to deal well with the steel stuctrure technology and ensure the construction quality. 关键词:建筑施工;钢结构;技术 Key words:building constuctrion;steel structure;technology 中图分类号:TU758.11 文献标识码:A 文章编号:1006—4311(2015)10-0101—02 O引言 构技术的把握。 我国建筑施工技术近年来得到了很大的提高,钢结构 1钢结构技术特点分析 技术在建筑施工中已得到广泛利用。在建筑施工中,钢结 在建筑施工中,钢结构技术得到广泛使用,原因在于 构技术属于一种新型技术,钢结构技术得到人们的认可, 钢结构建筑与传统的建筑结构相比,其更具有优势,钢结 主要原因是其具有良好的可塑性,与传统的材料相比,在 构具有以下优点:在施工当中采用钢结构技术所打造出来 建筑施工中更适合,在钢结构施工过程中,要注意对钢结 的钢结构建筑具有很大的优势,这与建筑特点存在紧密的 作者简介:孔祥伟(1980一),男,山东泰安人,工程师,研究方向为 联系,钢结构建筑施工,所需要的工期比较短,可以在短时 工业厂房钢结构、钢筋混凝土结构。 间内完成工程施工,施工当中采用的是流水线的施工方 大气温度,直至不采取措施而内表温差、表气温差均可控 制在规范的要求范围。 1 1结束语 高2℃,承台实测表面最高温度36℃,内外温差16℃,与软 件计算结果相近,并小于25℃规范要求。 克地坝陵河特大桥3号墩承台大体积混凝土于2013 年10月1O日下午18时开始浇筑,2013年10月14日下 午17时浇筑完成,历时95h,承台混凝土浇筑完对垫块底 部进行凿毛处理后,2013年l0月16日下午14时浇筑垫 块混凝土,2013年10月17日8时浇筑完成,历时18h。待 承台及垫块混凝土通水养护2d后,拆模观察其表面平整, 无温度裂缝产生。 承台混凝土浇筑第4、5天内部温度达到峰值时测量 冷却管进出水温度数据见表2。 表2 测温时间 年、①通过以上实例证明,采用Midas/FEA软件建立大体 积混凝土水化热的有限元分析模型,其计算结果准确,能 够正确动态模拟混凝土内部水化热和采取降温后内部水 化热的发展状态,并能动态模拟其降温过程。与传统公式 手算方法比较,其分析计算精度高,结果显示详细、直观。 ②采用Midas/FEA软件对大体积混凝土的施工实际 采用的冷却管措施进行分析,可以模拟出真实状态,对数 据分析及结果查看更为准确,更能有效地指导施工,为大 体积混凝土降温提供了更有力的帮助。 ③通过以上实例可以看出大体积混凝土温控措施的 重要性,在后续施工中如何保证温控措施得到有效控制是 作为施工人员的主要研究对象。 参考文献: [1】朱伯芳.大体积混凝土温度应力与温度控SfJ[M].北京:中国 电力出版社,1999. 月、日 时 (℃) 进水口 1 大气 {日r-tr 测点温度 ℃) 出水口 3 4# 进水口与出水 口温度差值 (℃) 20l3.10.14 17 22 2013.10.14 22 19 21.8 23.8 24.9 23.6 22.1 2.0/3.1/1.8/0.3 19.1 23.5 26.3 25.4 20.6 4.4/7.2/6.3/1.5 2013.1O.15 8 2O 2O13.1O.15 14 21 21.6 24.1 26.8 26.9 23.6 2.5/5.2/5.3/2.0 21.9 25.8 25.7 24.5 26.1 3.9/3.8,2.614.2 通过以上数据分析,混凝土在浇筑后在1—3d温度处 [2】张春阁,丁岩.基于Midas/Civil的大体积混凝土温度应力 于上升阶段,混凝土芯部的最高温度多数发生在浇筑后的 计算及其防裂技术措施fJ1-中国港湾建设,2012(4):17—19. 3~5d内,5d以后混凝土温度处于下降阶段。因此,在混凝 【3】李长瑞,杜嘉林.Midas/Civil在大体积混凝土承台水化热 Jl_山东交通科技,2011(1):58—61. 土浇筑过程中,应进行温度测量及冷却管通水降温,在混 控制中的应用『『4J杨培诚,李志咸.基于MIDASCIVIL的C40大体积混凝土 凝土浇筑后1~5d内应密切观测混凝土温度的变化,每2h J】.公路工程,2012(1):136—138. 采集数据一次,5d以后每6—8h采集数据一次,同时量测 施工期仿真分析[

因篇幅问题不能全部显示,请点此查看更多更全内容

Top